Background Image
Table of Contents Table of Contents
Previous Page  234 / 658 Next Page
Information
Show Menu
Previous Page 234 / 658 Next Page
Page Background

AN63880_E 12/13S

www.thermoscientific.com

©2013 Thermo Fisher Scientific Inc. All rights reserved. ISO is a registered trademark of the International Organization for

Standardization (Organisation Internationale De Normalization). RECIPE and ClinMass are registered trademarks of RECIPE Chemicals +

Instruments GmbH. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is pre-

sented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in

any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all

products are available in all countries. Please consult your local sales representative for details.

Thermo Fisher Scientific,

San Jose, CA USA is

ISO 9001:2008 Certified.

Application Note 593

Conclusion

The analysis of benzodiazepines for research purposes

presents a challenge due to their low concentrations, their

short half life, and their diversity. In this work, the

RECIPE ClinMass

®

complete kit for the quantification

of 33 benzodiazepines and metabolites in serum was

evaluated for research use with a TSQ Vantage triple

quadrupole. The online SPE configuration was achieved

by using a Transcend TLX-1 system. HPLC coupled to

tandem mass spectrometry may be a suitable tool for the

quantification of benzodiazepines in research applications

since it can deal with the differences in polarities of the

benzodiazepines and their metabolites. The use of SRM

detection increases the analytical specificity needed to

attain the low quantification ranges for these types of

molecules. Finally, the use of LC-MS/MS simplifies sample

preparation since the matrix clean-up is performed by

online SPE.

This research method showed good results in terms of

variability, precision, and dynamic range requirements for

a clinical research method.

For Research Use Only.

Not for use in diagnostic procedures.

Africa

+43 1 333 50 34 0

Australia

+61 3 9757 4300

Austria

+43 810 282 206

Belgium

+32 53 73 42 41

Canada

+1 800 530 8447

China

800 810 5118

(free call domestic)

400 650 5118

Denmark

+45 70 23 62 60

Europe-Other

+43 1 333 50 34 0

Finland

+358 9 3291 0200

France

+33 1 60 92 48 00

Germany

+49 6103 408 1014

India

+91 22 6742 9494

Italy

+39 02 950 591

Japan

+81 45 453 9100

Latin America

+1 561 688 8700

Middle East

+43 1 333 50 34 0

Netherlands

+31 76 579 55 55

New Zealand

+64 9 980 6700

Norway

+46 8 556 468 00

Russia/CIS

+43 1 333 50 34 0

Singapore

+65 6289 1190

Spain

+34 914 845 965

Sweden

+46 8 556 468 00

Switzerland

+41 61 716 77 00

UK

+44 1442 233555

USA

+1 800 532 4752