AI10382-GC-MS-Food Safety-Analysis - page 27

References
1. The Effect of the Autosampler Vial’s Glass Surface on
GC-MS Analysis of Pyrethroid Pesticides at ppb Levels:
Brian W King and Anila I Khan. Thermo Fisher
Scientific, Runcorn, UK. Poster Reference number
PSCCS 0512 588.
2. Ullmann's Encyclopedia of Industrial Chemistry,
Bernard H. W. S. De Jong, Ruud G. C. Beerkens, Peter
A. van Nijnatten, Eric Le Bourhis: Glass, 1.
Fundamentals, Published Online: 15 OCT 2011, DOI:
10.1002/14356007.a12_365.pub3, Wiley-VCH Verlag
GmbH & Co. KGaA, Copyright © 2002 by Wiley-VCH
Verlag GmbH & Co. KGaA
3. ISO 719:1985 Glass – Hydrolytic resistance of glass
grains at 98 degrees C – Method of test and
classification.
AN20642_E 10/12S
Application Note 20642
thermoscientific.com/crc
© 2012 Thermo Fisher Scientific Inc. All rights reserved. Vespel is a registered trademark of E. I. du Pont de Nemours and Company. All other trademarks are
the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc.
products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms
and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
USA and Canada
+1 800 332 3331
France
+33 (0)1 60 92 48 34
Germany
+49 (0) 2423 9431 20 or 21
United Kingdom
+44 (0)1928 534110
Japan
+81 3 5826 1615
China
+86 21 68654588 +86 10 84193588
+86 20 83145199 800 810 5118
India
+91 22 6742 9494 +91 27 1766 2352
Australia
1 300 735 292 (free call domestic)
New Zealand
0800 933 966 (free call domestic)
All Other Enquiries
+44 (0) 1928 534 050
Technical Support
North America
+1 800 332 3331
Outside North America
+44 (0) 1928 534 440
Conclusion
• Studies showed plastic and high purity clear neutral
borosilicate glass vials reduce adsorption of pyrethroids
at lower concentrations.
• The linearity and recovery of the pyrethroids was
improved by the use of polypropylene vials but at the
risk of absorbed material being introduced into the GC.
• The best results were obtained using a high purity 33
expansion clear glass vial with low surface activity,
which gave higher sample recovery compared to the
polypropylene vial.
• The SPE-GC/MS method demonstrated high recovery
for 0.10 ng/mL of pyrethroids in water.
• The GC/MS method was found to be linear over the
range of 50 to 2000 ng/mL.
• The HyperSep C18 silica SPE cartridge allowed the
extraction and preconcentration of pyrethroids in water
for quantification.
1...,17,18,19,20,21,22,23,24,25,26 28,29,30,31,32,33,34,35,36,37,...225