4'4-Methylenedianaline in Serum

Using 100mg 1mL HyperSep C18 Extraction Column

(Part Number: 60108-302)

Prepare Sample

None

Condition Verify-CX Extraction Column

3mL of methanol

3mL of DI H

2

O

Apply Sample

Load sample at 1mL/minute

Wash Column

1mL of DI H

2

O

Elute 4'4-Methylenedianaline

0.25mL of methanol containing 1 M ammonium hydroxide

Analysis

Inject 10µL onto HPLC system

Extracted 100 µg/mL sample

Retention time: 3.162 seconds

Mobile phase: methanol/water (50:50)

Flow rate: 1.2mL/min

Injection volume: 10µL

Wavelength: UV 254nm

Recommended HPLC Column

Part Number

Hypersil GOLD 5µm, 250 x 4.6mm

25005-254630

Environmental

Applications

Metal Extraction by SPE

Using HyperSep Aminopropyl, HyperSep Retain-AX, HyperSep SAX

and HyperSep Verify-AX Extraction Columns

Sample Preparation

Prepare sample as appropriate

Condition appropriate HyperSep Extraction Column

NOTE:

Column selection depends on volume of sample,

concentration of metal to be extracted

For a 1mL column

1 x 3mL CH

3

OH

1 x 3mL H

2

O

NOTE:

Do not allow the cartridge to dry out

Apply Sample

Load 10 to 50mL of sample water at 1 to 3mL/minute

Wash Column

1 x 10mL H

2

O

Dry column (1 minutes at >10"Hg)

Elute

Acid

Prepare 100mM nitric acid solution

1 x 3mL of nitric acid (100mM ) solution to the column

Flow through at 1 to 3mL/minute

Dilute eluant with H

2

O for analysis

Base

1 x 3mL of triethylamine to the column

Flow through at 1 to 3mL/minute

Dilute eluant with H

2

O for analysis

Analysis

Prepare calibration curves for use with atomic absorption

(AA) or Inductively

Coupled Plasma Atomic Emission Spectroscopy (ICP-AES)

using appropriate metals standards