Background Image
Table of Contents Table of Contents
Previous Page  314 / 658 Next Page
Information
Show Menu
Previous Page 314 / 658 Next Page
Page Background

Part of Thermo Fisher Scientific

For Research Use Only. Not for use in diagnostic procedures.

www.thermoscientific.com

Legal Notices: ©2010 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This

information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any

manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all

countries. Please consult your local sales representative for details.

Thermo Fisher Scientific,

San Jose, CA USA is ISO Certified.

AN63200_E 11/10S

In addition to these

offices, Thermo Fisher

Scientific maintains

a network of represen-

tative organizations

throughout the world.

Africa-Other

+27 11 570 1840

Australia

+61 3 9757 4300

Austria

+43 1 333 50 34 0

Belgium

+32 53 73 42 41

Canada

+1 800 530 8447

China

+86 10 8419 3588

Denmark

+45 70 23 62 60

Europe-Other

+43 1 333 50 34 0

Finland/Norway/

Sweden

+46 8 556 468 00

France

+33 1 60 92 48 00

Germany

+49 6103 408 1014

India

+91 22 6742 9434

Italy

+39 02 950 591

Japan

+81 45 453 9100

Latin America

+1 561 688 8700

Middle East

+43 1 333 50 34 0

Netherlands

+31 76 579 55 55

New Zealand

+64 9 980 6700

Russia/CIS

+43 1 333 50 34 0

South Africa

+27 11 570 1840

Spain

+34 914 845 965

Switzerland

+41 61 716 77 00

UK

+44 1442 233555

USA

+1 800 532 4752

Within-day and between-days precisions were de-

termined with QC samples prepared by spiking blank

urine to three concentrations: twice the lowest standard

concentration (QC1), the middle of the calibration range

concentration (QC2), and 80% of the highest standard

concentration (QC3).

Table1: Calibration ranges, within-day precision, and between-days precision

for the lowest QC sample.

Calibration

Within-day

Between-days

Analyte

range (ng/mL)

(%RSD)

(%RSD)

Citalopram

1-1000

10.7

9.3

Fluoxetine

10-1000

10.4

9.1

Norfluoxetine

10-1000

16.4

11.0

Mirtazapine

1-1000

13.6

12.5

Paroxetine

10-1000

10.2

14.6

Sertraline

10-1000

8.0

15.7

Trazodone

1-1000

11.7

10.6

Venlaflaxine

1-1000

13.6

12.1

Diphenhydramine

1-1000

7.1

7.1

Chlorpheniramine

1-1000

8.2

7.2

Pheniramine

1-1000

7.6

5.6

Cetirizine

5-1000

15.4

15.1

Promethazine

50-1000

4.6

4.2

Nicotine

5-1000

10.7

7.1

Cotinine

5-1000

12.0

8.1

Dextromethorphan

1-1000

8.6

10.9

Topiramate

50-1000

13.2

10.4

Orphenadrine

1-1000

7.2

9.1

Lidocaine

1-1000

11.5

9.4

Phenteramine

10-1000

11.1

13.8

Mesoridazine

5-1000

3.4

4.4

Midazolam

1-1000

14.3

12.2

Chlorpromazine

5-1000

8.0

15.0

Promazine

5-1000

17.1

10.8

Trifluoperazine

5-1000

7.9

17.5

Diltiazem

1-1000

10.1

10.2

Metaprolol

5-1000

10.0

8.5

Verapamil

5-1000

8.7

9.2

Doxylamine

1-1000

14.4

11.7

Hydroxyzine

1-1000

17.9

14.0

Conclusion

An efficient (9 minute), sensitive (LOQ of 1-50 ng/mL),

and precise LC-MS/MS method using TurboFlow tech-

nology was developed for the quantitation of 30 drugs

in human urine. In clinical research, TurboFlow technol-

ogy simplifies sample preparation and improves method