

Africa-Other
+27 11 570 1840
Australia
+61 3 9757 4300
Austria
+43 1 333 50 34 0
Belgium
+32 53 73 42 41
Canada
+1 800 530 8447
China
+86 10 8419 3588
Denmark
+45 70 23 62 60
Europe-Other
+43 1 333 50 34 0
Finland/Norway/Sweden
+46 8 556 468 00
France
+33 1 60 92 48 00
Germany
+49 6103 408 1014
India
+91 22 6742 9434
Italy
+39 02 950 591
Japan
+81 45 453 9100
Latin America
+1 561 688 8700
Middle East
+43 1 333 50 34 0
Netherlands
+31 76 579 55 55
New Zealand
+64 9 980 6700
Russia/CIS
+43 1 333 50 34 0
South Africa
+27 11 570 1840
Spain
+34 914 845 965
Switzerland
+41 61 716 77 00
UK
+44 1442 233555
USA
+1 800 532 4752
www.thermoscientific.com©2013 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization.
All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are
subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
Application Note
10336
Thermo Fisher Scientific,
Austin, TX USA is
ISO 9001:2013 Certified.
AN10336_E 07/13S
Conclusion
• The TSQ Quantum XLS Ultra GC-MS/MS is a highly
sensitive and selective system applicable to dioxins
and furans analysis in a range of environmental sample
types and generates results that perform within current
in-house QC criteria.
• Some differences arise in the calculated concentration
between the GC-MS/MS and GC-HRMS analysis.
These are thought to be related to the differences in the
selectivity mechanism of each system.
• GC-MS/MS applied to PCDD/Fs still allows for full
isotope dilution quantitation as currently used by
GC-HRMS systems. TargetQuan 3 software can be
used with the TSQ Quantum XLS Ultra to provide
the specific calculations required.
• The Thermo Scientific
™
Dionex
™
ASE
™
Accelerated
Solvent Extractor system allows for unattended,
efficient extractions from all samples and enabled
recoveries well within QC criteria.
References
1. Ingelido, A. M.; Brambilla, G.; Abballe, A.;
di Domenico, A.; Fulgenzi, A. R.; Iacovela, N.; Lamiceli,
L.; Valentini, S.; De Felip, E.
Rapid Commun. Mass
Spectrom.
2012
, 26
(3), 236–242.
2. Kotz, A.;, Malisch, R.; Wahl, K.; Bitomsky, N.;
Adamovic, K.; Gerteisen, I.; Leswal, S.; Schächtele, J.;
Tritschler, R.; Winterhalter, H.
Organohalogen Compd.
2011
, 73
, 688–691.
3. Silcock, P.; Krumwiede, D.; de Dobbeleer, I.;
Huebschmann, H. J.; Kotz, A.
2011
, Thermo
Scientific Application Note 52266.