Background Image
Previous Page  105 / 144 Next Page
Information
Show Menu
Previous Page 105 / 144 Next Page
Page Background

105

Forensic

Applications

Methaqualone in Urine, Blood, Plasma/Serum

for GC or GC/MS Confirmations

Using 200mg 10mL HyperSep Verify-CX Extraction Column

(Part Number: 60108-742)

Prepare Sample

To 2mL of urine, blood, plasma/serum, add internal standard*

and 1mL of 100mM phosphate buffer (pH 6.0)

Mix/vortex

Add 2mL of 100mM phosphate buffer (pH 6.0)

Mix/vortex

Sample pH should be 6.0±0.5

Adjust pH accordingly with 100mM monobasic or dibasic

sodium phosphate

Centrifuge as appropriate

Condition Verify-CX Extraction Column

3mL of CH

3

OH then aspirate

3mL of DI H

2

O then aspirate

1mL of 100mM phosphate buffer (pH 6.0)

NOTE:

Aspirate at <3"Hg to prevent sorbent drying

Apply Sample

Load sample at 1 to 2mL/minute

Wash Column

3mL of DI H

2

O

Dry column (5 minutes at >10"Hg)

2mL of hexane

Elute Methaqualone

3mL of hexane/ethyl acetate (50:50); collect eluate

Dry Eluate

Evaporate to dryness at <40°C

Reconstitute with 100µL ethyl acetate

Quantitate

Inject 1 to 2µL onto gas chromatograph

For mass spectrometry, monitor the following ions:

Compound

Primary Ion** Secondary

Tertiary

Methaqualone

235

250

233

Hexobarbital*

221

157

156

Methaqualone-D7*

240

257

240

* Suggested internal standard

** Quantitation ion

Recommended GC Columns

Part Number

TRACE TR-DoA5 Column, 15m x 0.25mm x 0.25µm

26AF130P

TRACE TR-DoA35 Column, 15m x 0.20mm x 0.33µm

26AC497P

Methadone in Urine for GC or GC/MS Confirmations

Using 200mg 10mL HyperSep Verify-CX Extraction Column

(Part Number: 60108-742)

Prepare Sample

To 2mL of urine add internal standard* and 1mL of

100mM phosphate buffer (pH 6.0)

Mix/vortex

Sample pH should be 6.0±0.5

Adjust pH accordingly with 100mM monobasic or dibasic

sodium phosphate

Condition Verify-CX Extraction Column

3mL of CH

3

OH then aspirate

3mL of DI H

2

O then aspirate

1mL of 100mM phosphate buffer (pH 6.0)

NOTE:

Aspirate at <3"Hg to prevent sorbent drying

Apply Sample

Load sample at 1 to 2mL/minute

Wash Column

3mL of DI H

2

O

1mL of 100mM acetic acid

3mL CH

3

OH

Dry column (5 minutes at >10"Hg)

Elute Methadone

3mL of CH

2

Cl

2

/IPA/NH

4

OH (78:20:2)

Collect eluate at 1 to 2mL/min

NOTE:

Prepare elution solvent fresh daily; add IPA/NH

4

OH mix,

then add CH

2

Cl

2

(pH 11-12)

Concentrate

Evaporate to dryness at <40°C

Reconstitute with 100µL acetonitrile

Quantitate

Inject 1 to 2µL onto gas chromatograph

For mass spectrometry, monitor the following ions:

Compound

Primary Ion** Secondary

Tertiary

D

9

-Methadone*

78

226

303

Methadone

72

223

294

* Suggested internal standard

** Quantitation ion

Recommended GC Columns

Part Number

TRACE TR-DoA5 Column, 15m x 0.25mm x 0.25µm

26AF130P

TRACE TR-DoA35 Column, 15m x 0.20mm x 0.33µm

26AC497P